Posted on November 20, 2009Tissue Bath Equipment Can Provide Many Answers
Tissue bath procedures and equipment have been around for over a hundred years. This technique of isolating specific types of tissue and then exposing them to various changes is invaluable in research.
Data Acquisition Articles
Posted on November 20, 2009Skin Conductance One Of The Fastest Ways To Test Stress
Our skin is the largest organ of our body and skin conductance tests are becoming more and more commonplace. Testing the electrodermal response in the skin can give clues to the state of the autonomic nervous system as well as the internal stress...
Posted on November 20, 2009A Pressure Transducer Translates Many Different Types Of Body Movements.
When it comes to translating one type of pressure into another type of signal, a pressure transducer is a major part of the medical industry. These durable workhorses handle everything from translating blood pressure to determining lung volume and...
Posted on November 20, 2009Nerve Stimulators Help Reduce Pain Without Chemical Means.
One of the newer uses for nerve stimulators is to help reduce chronic pain. Several different approaches have been developed and while most of the pain addressed in muscular or arthritic in nature there are also approaches for everything from...
Posted on November 20, 2009An ECG Sensor Can Contribute To Many Different Diagnoses
A basic ECG sensor test can gather a wide range of information. These sensitive workhorses of the medical world measure the electrical activity of the heart and provide a number of clues that can lead to a more accurate diagnosis.
Posted on November 20, 2009When It Comes To Data Acquisition Systems, Input Usually Winds Up In The Digital Real
Data acquisition systems have become such a part of the medical profession that we take for granted the ability to translate information into a form that can be measured and tracked. But for most systems, the best way for the signal to travel is in...
Posted on November 20, 2009Medical And Scientific Amplifiers Let Us Notice Details
We’re used to thinking of amplifiers as something that boosts sound, but in the medical and scientific fields they boost whatever signal is input into them. In many cases this allows a very small signal strength to be captured, amplified and then...
Posted on October 15, 2009Data Acquisition Means More Than Just Details
Data acquisition is crucial for a number of different fields, including medicine and science. But along with the sensors and different types of input devices that feed data into the systems, there are sophisticated programs that organize the details...
Posted on October 25, 2007Softbit Standards Specification for AC Electric Motors
A full load test at full copper loss - the motor is coupled to a load, as close to full load as the test facility will allow, the voltage reduced until full load current is reached and the motor run until thermal equilibrium is reached.
Posted on October 25, 2007Selection of AC Electric Motors
The amount of bearing wear can be determined by measuring the air gap between the stator and rotor. Measuring of air-gap between the rotor and the stator on both sides and the bottom is the accepted method. Large motors have one bearing insulated...
Posted on October 25, 2007Maintenance of AC Electric Motors
During normal operation the slip rings acquire a protective coating that contains copper oxide and graphite with absorbed water as a result of several weeks of operation. This film of coating serves as a lubricant that reduces brush wear. Operating...
Posted on October 25, 2007Installation & Commissioning of AC Electric Motors
Installation should be carried out by qualified and experienced personnel. The following points should be noted before installation and commissioning of motors:- The motor foundation must rigidly support all four feet of the motor in the same plane.
Posted on October 3, 2007Factors affecting the Design of an ac electric induction motor 2
The value of cooling co-efficient while designing an ac electric motor depends upon the ventilation conditions in the ac electric motor. An ac electric motor with better ventilation has a lower value of cooling co-efficient. If the current density in...
Posted on October 2, 2007Factors affecting the Design of an ac electric induction motor1
Factors affecting the Design of an ac electric induction motor Design of an ac electric motor is directly affected by the length of the air gap. Ampere Conductors value also affects the design of an ac electric motor.
Posted on October 2, 2007AC Electric Motor Design - Software1
AC Electric Motor Design - Software Softbit presents an easy way to design LT, 3 ph, TEFC, squirrel cage ac electric motors with the help of "AC Electric Motor Design Software". You just need to enter a few preliminary inputs and click a button....
Posted on September 13, 2007HT Distribution and Power Transformer Design Software
HT Distribution and Power Transformer Design Software This transformer design software can get you the design parameters along with CAD developed images of different transformer & core assembly parts dynamically. This CAD feature helps you to...
Posted on September 13, 2007Electrical Panel Design Software
Generates: Generates data sheets as bill of materials. estimation & costing. GA drawings, Farication drawings, Bus-Bar chart, Cut-out (Mechanical) design. Auto-generation - single line diagrame (SLD).